Siemens IEEE802.11 Instrucciones de operaciones Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
107
5.4.12
WLAN Statistics
5.4.12.1
Errors
The WBM page show how many bad frames were received or sent per WLAN interface. If an
increased number of errors occurs, you should check the settings for the WLAN interface(s),
the setup of the devices and the connection quality.
Description
The Tx Errors table has the following columns:
Interface
Shows the WLAN interface to which the entries apply.
Error types
The other columns after the WLAN interface contain the absolute numbers of the frames
sent according to their error type.
The columns of the table distinguish the following error types:
Transmission Errors
Shows the number of bad frames that were sent.
Dropped Frames
Shows the number of frames that were discarded.
Despite all the retries, the frame could not be successfully sent.
The frame has not yet been sent and the recipient has logged off in the meantime.
Retry Count
Shows the number of frames sent successfully that required one or more retries.
Vista de pagina 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 291 292

Comentarios a estos manuales

Sin comentarios