Technical basics
3.4 iREF
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
34 Configuration Manual, 11/2014, C79000-G8976-C323-03
In particular in applications in which MIMO cannot be used or brings no advantage, this
allows data to be transmitted at the highest possible data transmission rate.
You configure iREF in "iFeatures > iREF"
Requirement
To be able to use iREF, the device must have at least 2 activated antennas.
Restrictions
A maximum data rate of only up to 150 Mbps (MCS 0 - 7 or 1 x spatial stream) is possible
iREF cannot be used along with other iFeatures (for example iPCF or iPCF-MC)
Advantages
Due to the directional data transmission and dynamic deactivation of antennas that do not
radiate in the direction of the particular client, interference can be reduced.
The signal strength is improved because the active antenna always has the maximum
permitted transmit power available.