Configuring with Web Based Management
5.10 "iFeatures" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
263
IP Address
The IP address of the devices accessible to the client. If necessary, you can change the
IP address.
Resolver IP Address
The IP address with which the permitted IP address is resolved. The entry is necessary
when the management IP address is located in a different subnet.
If the IP address "0.0.0.0" is configured for "Resolve IP Address", the management IP
address is used for resolution.
5.10
"iFeatures" menu
5.10.1
iPCF
Note
This WBM page can only be configured with the following KEY
-PLUGs:
Access point: W780 iFeatures (MLFB 6GK5 907-8PA00)
Client: W740 iFeatures (MLFB 6GK5 907-4PA00)
When should iPCF be used?
The use of iPCF is advisable particularly if you have a large number of nodes and want to
implement highly deterministic operation. This is necessary, for example with PNIO or other
cyclic protocols. You will find a more detailed description of iPCF in the section "Technical
basics" in the section "iPCF / iPCF-MC".
Note
iPCF and iPCF-MC are not compatible with each other and cannot be used at the same
time on a device.
The possible settings differ for access point and client. Below, both will be described.