Configuring with Web Based Management
5.9 "Security" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
253
Description
Table 1 has the following columns:
Column 1
All ports shows that the settings will be adopted for all ports of table 2 after clicking the
"Copy to Table" button.
within own VAP / with other VAPs / with Ethernet
In the drop-down list, select the settings for all ports of table 2. If "No Change" is selected,
the entry in table 2 remains unchanged.
Copy to Table
If you click the button, the settings are adopted for all ports of table 2.
Table 2 has the following columns:
Radio
Shows the available WLAN interfaces.
Port
Shows the VAP interface.
within own VAP
Enabled
Clients logged on to the same VAP interface of an access point can communicate with
each other.
Disabled
Option is disabled.
with other VAPs
Enabled
Clients logged on to different VAP interfaces of an access point can communicate with
each other.
Disabled
Option is disabled.
Note
For an Access Point ,
"with other VAP" must be enabled on all WLAN interfaces or on
all VAPs to allow communication between clients logged on at different VAP interfaces
of the access point.
with Ethernet
Enabled
Clients can communicate via the Ethernet interface of the access point.
Disabled
Option is disabled.