Installing Primary AC Power, Continued
Verify that the correct fuses are in place. Fuses are located on the PECM. See diagram below for
correct placement.
Fuses for
115VAC
Fuses for
230VAC
F1
AC Power Circuit 1
16A
(1901693-001)
10A
(1901694-001)
F5
Heater Channel 6
6.3A
(1901695-001)
6.3A
(1901695-001)
F2
AC Power Circuit 2
16A
(1901693-001)
10A
(1901694-001)
F4
LWH 1-5 (low wattage
heaters)
10A
(1901694-001)
10A
(1901694-001)
F3
Power Supply (24V out)
3.15A
(1302004-033)
3.15A
(1302004-033)
WARNING No substitutes should be used for the fuses noted above. Most of these are sand-
filled ceramic fuses with a very fast acting fuse to protect the heater relays. A fuse kit is available
on page 42 which contains all of the listed fuses.