Siemens TCP/IP Ethernet Driver Help
Note:
Automatic Tag Database Generation is only supported for the S7-300 and S7-400 device models.
Unable to generate a tag database for device <device name>. Reason: Failed
to read data from the STEP 7 project.
Error Type:
Warning
Possible Cause:
One of the files in the STEP 7 project folder is missing, invalid, or corrupt.
Solution:
Verify that the entire STEP 7 project folder is available at the location specified in the S7 project file parameter
(located in the Tag Import tab of Device Properties).
See Also:
Tag Import
Unable to generate a tag database for device <device name>. Reason: File
system error processing the STEP 7 project.
Error Type:
Warning
Possible Cause:
1. The STEP 7 project is in use and is locked.
2. The STEP 7 project is not accessible.
3. The disk is full or write-protected.
Solution:
1. Ensure that the STEP 7 project is not in use.
2. Ensure that the STEP7 project's file location is accessible and that its user permissions allow access.
3. Ensure that the disk is not full or write-protected.
Note:
The folder that contains the STEP 7 project file must be complete with all sub-folders and files.
See Also:
Tag Import
Unable to generate a tag database for device <device name>. Reason: Internal
driver error occurred.
Error Type:
Warning
Possible Cause:
Tag generation was unable to start due to an unknown error.
Solution:
Retry the tag generation.