Setting-up
4.2 Limit stops
Manual Machine Plus Turning
Programming and Operating Manual, 06/2009, 6FC5398-6CP10-1BA0
27
Parameter
Parameter Description
ON The limit stop is activated.
OFF The limit stop is deactivated.
- X Negative absolute position of the limit stop of the X axis.
The axis stops automatically if:
• The limit stop is active.
• The specified axis traverses in the negative direction and reaches the absolute limit stop position.
+X Positive absolute position of the limit stop of the X axis.
The axis stops automatically if:
• The limit stop is active.
• The specified axis traverses in the positive direction and reaches the absolute limit stop position.
-Z Negative absolute position of the limit stop of the Z axis.
The axis stops automatically if:
• The limit stop is active.
• The specified axis traverses in the negative direction and reaches the absolute limit stop position.
+Z Positive absolute position of the limit stop of the Z axis.
The axis stops automatically if:
• The limit stop is active.
• The specified axis traverses in the positive direction and reaches the absolute limit stop position.
All of the limit stops are set in the following screen.
Figure 4-4 All limit stops set