Vista de pagina 60
UM344-2 INSTALLATION
September 1995
4
-
27
Digital LCD Meter
Meter Mounting
Screw, qty. 2
Notes 1, 2 and 3
Cable connectors
J1 to J4 wired
in parallel
Disconnect
Cable
Cable guide
slot (4 places)
X02870S1
Meter Repositioned 90 CCW
o
Meter Repositioned 180
o
Notes:
1. Meter can be rotated clockwise or counterclockwise
either 90 (actually, 78 and 282 respectively) or 180 .
2. Remove Enclosure Cap for access to Meter.
3. Move Meter mounting screws when repositioning Meter
90 CW or CCW.
o
o o
o
o
Factory Meter Orientation 0
Shown with Enclosure Cap Removed
o
FIGURE 4-10 Digital Meter Repositioning and Removal
C. Installation
1. Turn off power to transmitter and remove the longer enclosure cap.
2. Snap wrist strap on wrist and connect ground clip to an unpainted area on the Transmitter or
mounting bracket.