Siemens EF 83H Series Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 187
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Communication Services
4-6
SIMATIC 505 PROFIBUS-FMS CP User Manual
Overview (continued)
4. The
programmable logic controller recognizes the WX bit transition to
1, and then resets the WY bit to 0.
5.
The FMS CP module completes the job, stores the job status in
programmable logic controller V
-memory
, and, when it sees WY bit
reset to 0, resets the WX bit to 0.
6.
The programmable logic controller sees WX return to 0, indicating that
the job is complete. It can check the status word for errors: if none, the
programmable logic controller knows that the data was sent/received
successfully.
7.
The programmable logic controller can start the job again, whenever it
is ready
, by repeating the sequence from Step 2.
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 186 187

Comentarios a estos manuales

Sin comentarios