When connecting multiple instruments, for distinguishing instruments, each instrument must
be set C84 value with a different parameter. .
3、Must press “FUNC+PARA” to set the parameter;
4、PROG. have 19 numbers and SEG have 30 numbers, press DOWN key (sub) and PROG key
(add) to change program number;
5、Press “FUNC+PROG” to change the program.----every program must be set firstly and then
communicate will be ok, or else “PLC Response Error” will print;
6、After “RUN/HLD” light on, many parameters can’t be modified(e.g. SET) In order to reset, press
“ PROG+RUN/HOLD” .
Modify the parameter at the state of “DISP”, not at the state of “INPUT”;
7、On the temperature controller, time parameters show number with sexagesimal.
( Example it shows 2222 on the screen, but on the controller panel shows
37.02-----37.00*60+2=2222)
8、PROG’s address setting:
FBR1_R indicates prog 1. (e.g. PROG 1) format: DDD.DD. Main address DDD indicates seg
No, subaddress DD indicates parameter value, the correspondence as follows
(Example:FBR1_R address 11.10 indicates PROG 1,SEG 1,T1 2nd )
Sub addr DD correspond to temperature controller:
Sub Addr Parameter Sub Addr Parameter
.0 SP .12 T2 2nd
.1 TM .13 T3 1st
.2 None(Skip) .14 T3 2nd
.3 EV1 .15 T4 1st
.4 Blank .16 T4 2nd
.5 EV2 .17 T5 1st
.6 Blank .18 T5 2nd
.7 EV3 .19 PID
.8 Blank .20 None(Skip)
.9 T1 1st .21 9.5.
.10 T1 2nd .22 9.5.to
.11 T2 1st
SDC36(Please refer to the manual of yamatake SDC36 for details)
Device Bit Address Word Address Format Notes
Data Register ———— 4X 0-65535 DDDDD
DMC(Please refer to the manual of DMC-SPL for details, in 10-8 communication parameters)
Device Bit Address Word Address Format Notes
Data Register ———— 4X 1002-65535 DDDDD
Address add 1 to the list of
communication parameters
Example: ch1 pv is according to 4x1005 in the EV5000.