KINCO
235
Trio controller communication settings
Omron protocol:
define Host Link slave node
HLS_NODE=1
define Host Link slave mode code
HLS_MODEL=$FA
Set up Host Link slave for port 2
Trio controller setting:SETCOM (baudrate, databits, stopbits, parity, port, 5)
SETCOM(9600,7,2,2,2,5)
MC controller unit can communicate with plc terminal after setting the configuration.
Note:A is the programming port of controller,B is the communication port.
Modbus Protocol:
address=1
Setcom (9600, 8, 1, 0, 1, 4)
Supported Device
TRIO
Device Bit Address Word Address Format Notes
I/O and Internal Auxiliary Relay IR0.0-1023.15 ———— DDDD.DD
Data Memory ———— DM0-30000 DDDDD
Note:
Address correspondence: IRn.m-->the m Trio VR (n); DMn->Table (n). Example IR1.02
corresponds to the 2nd bit of VR1.
Modbus RTU Extend
Device Bit Address Word Address Format Notes
Data register bit 4X_bit 0.0-1023.15 ———— DDDD.DD