Configuring Networks
3-20
SIMATIC NET Twisted-Pair and Fiber-Optic Networks
C79000-G8976-C125-02
Example
The following example once again illustrates how to configure a network when
mixing OSMs, OLMs, ELMs, and star couplers. The individual transmission paths
must be checked.
Critical paths are those in which the signal runs through long sections of cable and
a lot of network components between two nodes.
The connection between node 1 and node 3 represents a critical path. Node 3 is
connected to OLM 4 in the redundant ring. In redundant ring structures, make sure
that the worst-case situation is assumed for the connection during configuration.
This means that a connection that is only used redundantly must also be included
although this represents a detour in the normal mode.