Vista de pagina 259
Network Topologies with OSM/ESM
Industrial Ethernet OSM/ESM
32
C79000-Z8976-C068-04
3.4 Compatibility of OSM Version 2/ESM with OSM/ORM Version
1
Compatibility
Version 2 OSMs can be operated at the same time in the ring with the OSM (6GK
1105-0AA00) and ORM (6GK 1105-1AA00) here called OSM/ORM Version 1. Make
sure that only one device can adopt the redundancy manager function in the ring; in
other words, only one ORM or only one OSM Version 2 operating in the RM mode.
ORM
OSM ITP 62
OSM
OSM ITP 62
1 Fiber-optic cable (FO)
OSM
Figure 13: Ring with ORM as Redundancy Manager