Interfaces, Displays and Operator Controls
Industrial Ethernet OSM/ESM
52
C79000-Z8976-C068-04
Display mode Meaning
Fault mask
The fault mask indicates whether the ports
and the power supplies are monitored with the
signaling contact.
Port LED
- Lit green: Port is monitored; in other words,
if the port does not have a valid connection
(for example cable not plugged in or
attached device turned off), the signaling
contact is triggered.
- Not lit: The port is not monitored; in other
words, an invalid or valid connection at the
port does not trigger the signaling contact.
The fault mask can be set again with the
button on the front panel of the OSM (see
4.2.4.2)
The basic status "Port Status" of the display is adopted automatically after turning on
the device. The device also switches automatically to this display status when the
"Select/Set" button is pressed for more than a minute.
LED on LED on
Display