Semiconductor Group 6-15
On-Chip Peripheral Components
C501
6.2.1.1 Timer/Counter 0 and 1 Registers
Totally six special function registers control the timer/counter 0 and 1 operation :
TL0/TH0 and TL1/TH1 - counter registers, low and high part
TCON and TMOD - control and mode select registers
Special Function Register TL0 (Address 8A
H
) Reset Value : 00
H
Special Function Register TH0 (Address 8C
H
) Reset Value : 00
H
Special Function Register TL1 (Address 8B
H
) Reset Value : 00
H
Special Function Register TH1 (Address 8D
H
) Reset Value : 00
H
Bit Function
TLx.7-0
x=0-1
Timer/counter 0/1 low register
THx.7-0
x=0-1
Timer/counter 0/1 high register
.7 .6 .5 .48A
H
TL0
Bit No.
76543210
MSB LSB
.3 .2 .1 .0
.7 .6 .5 .48C
H
TH0.3 .2 .1 .0
.7 .6 .5 .48B
H
TL1.3 .2 .1 .0
.7 .6 .5 .48D
H
TH1.3 .2 .1 .0
Operating Mode Description
0 “TLx” holds the 5-bit prescaler value.
1 “TLx” holds the lower 8-bit part of the 16-bit timer/counter value.
2 “TLx” holds the 8-bit timer/counter value.
3 TL0 holds the 8-bit timer/counter value; TL1 is not used.
Operating Mode Description
0 “THx” holds the 8-bit timer/counter value.
1 “THx” holds the higher 8-bit part of the 16-bit timer/counter valu
e
2 “THx” holds the 8-bit reload value.
3 TH0 holds the 8-bit timer value; TH1 is not used.