EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 8
8187 PLC program error
see 8175.
8188 Gear command invalid
see 8175.
8189 Invalid channel assignement
see 8175.
8190 Invalid channel within message
8191 Invalid jog feed unit
8192 Invalid axis in command
8193 Fatal PLC error
see 8175.
8194 Thread without length
8195 No thread slope in leading axis
Remedy: Program thread pitch
8196 Too manny axis for thread
Remedy: Program max. 2 axes for thread.
8197 Thread not long enough
Cause: Thread length too short.
With transition from one thread to the other
the length of the second thread must be
sufficient to produce a correct thread.
Remedy: Longer second thread or replace it by a
linear interpolation (G1).
8198 Internal error (to manny threads)
see 8175.
8199 Internal error (thread state)
Cause: Internal error
Remedy: Restart software or reinstall when neces-
sary, report to EMCO, if repeatable.
8200 Thread without spindle on
Remedy: Switch on spindle
8201 Internal thread error (IPO)
see 8199.
8201 Internal thread error (IPO)
see 8199.
8203 Fatal AC error (0-ptr IPO)
see 8199.
8204 Fatal init error: PLC/IPO running
see 8199.
8205 PLC Runtime exceeded
Cause: Insufficient computer performance
8206 Invalid PLC M-group initialisation
see 8199.
8207 Invalid PLC machine data
see 8199.
8208 Invalid application message
see 8199.
8211 Feed too high (thread)
Cause: Thread pitch too large / missing, Feed for
thread reaches 80% of rapid feed
Remedy: Program correction, lower pitch or lower
spindle speed for thread
9001 unknown parameter !
Cause: SPS diagnosis, unknown parameter
entered
9002 Par.-number not allowed !
Cause: SPS diagnosis, unknown parameter
number entered
9003 unknown display-format !
SPS-diagnosis
9004 DB not existant !
SPS-diagnosis
9005 DW not existant !
SPS-diagnosis
9006 Invalid COM-port !
SPS-diagnosis
9007 Data-transmition activ !
data I/O
9011 No files found !
data I/O
9014 File already exists !
data I/O
9015 Error while opening file !
data I/O
9016 Error while reading file !
data I/O: error while opening a file
9017 Error while writing file !
data I/O: error while writing a file
9018 Invalid COM configuration !
data I/O
9019 No digitizer initial data foand !
Cause: a digitizer was set, but not calibrated
Remedy: calibrate digitizer (set edge points), see
"External Input Devices"
9020 No valid input !
Cause: digitizer was activated on invalied field
9021 COM-port is already used !
Cause: Another device is already connected to this
COM port.
9022 Digitizer not connected
Remedy: Connect digitizer, switch on ...