EMCO WINNC SINUMERIK 810/820 T ALARMS / MESSAGES
H 4
2520 ORDxx RS485 device absent
Cause: With program start not all necessary RS485
participant were present or while program
run a participant failed.
(AC) Axis controller
(SPS) PLC
(MT) Control keyboard
Remedy: switch on RS485 participant (machine,
control keyboard), check cables and
connectors, check terminator plug, report
to EMCO if repeatable
2521 ORDxx RS485 communication error
Remedy: switch off / on the PC, report to EMCO if
repeatable
2522 ORDxx RS485 communication error
Cause: internal error
Remedy: switch on/off PC, report to EMCO if
repeatable
2523 ORDxx INIT error on RS485 PC-board
see "Installation of the Software, Mistakes with In-
stallation of the Software"
2524 ORDxx Gen.-Failure RS485 PC-board
Remedy: switch off/on PC, report to EMCO if
repeatable
2525 ORDxx Transmit error RS485
Remedy: check RS485 cables and connectors, check
terminator plug, check for external
electromagnetic interferences
2526 ORDxx Transmit error RS485
see 2525
2527 ORDxx Internal error AC
Remedy: switch off/on machine, report to EMCO if
repeatable
2528 ORDxx Operating system error PLC
Remedy: switch off/on machine, report to EMCO if
repeatable
2529 ORDxx External keyboard error
Remedy: The control keyboard must be switched on
after the PC when it is connected to RS232,
switch off/on external keyboard, report to
EMCO if repeatable
2540 ORDxx Error on storing setting-data
Cause: hard disk full, wrong path determined, mis-
sing write access
Remedy: check hard disk, if repeatable reinstall
software
2545 ORDxx Drive / Device not ready
Remedy: insert disk, close drive
2546 ORDxx Checksum error machine-data
Remedy: report to EMCO if repeatable
2550 ORDxx PLC simulation error
Remedy: report to EMCO if repeatable
2551 ORDxx PLC simulation error
Remedy: report to EMCO if repeatable
2562 Read error on CNC program
Cause: error of program file, disk or hard disk error
Remedy: solve problem on DOS level, eventually
reinstall software
2614 Nxxxx Internal error MSD
Remedy: report to EMCO if repeatable
2650 Nxxxx Wrong Cycle-Call
Cause: invalid cycle call, if cycle will be called with
G code
Remedy: report to EMCO if repeatable
2849 Nxxxx Internal error CRC
Remedy: report to EMCO if repeatable
2904 Nxxxx Helix Z path too large
The angle between the helix and the tangent to the
arc must be less than 45°.
Remedy: correct program
3000 Nxxxx General Program error
Cause: no circle parameter programmed, wrong
plane for circle (G17/18/19), chamfer/
radius/thread pitch already programmed,
thread pitch missing, ...
Remedy: correct program
3001 Nxxxx More than 5 geomety parameter
Cause: wrong parameter for contour draft
Remedy: correct program
3002 Nxxxx Polar/radius error
Cause: No centre point specified, centre point in
wrong plane (G17/18/19)
Remedy: correct program
3003 Nxxxx Invalid address
The entered address is not allowed.
Remedy: correct program
3004 Nxxxx CL800 Error
Cause: general cycle error with cycle language CL-
800, wrong parameter, invalid value,
incorrect contour program, M17 in contour
program missing
Remedy: correct program
3005 Nxxxx Contour definition error
Cause: no valid contour draft with the programmed
coordinates, invalid parameter, invalid
values
Remedy: correct program
Comentarios a estos manuales