EMCO WINNC SINUMERIK 810/820 T
C 7
OPERATING SEQUENCES
Input pattern for data output - printer
Data Output
• Press softkey DATA OUT.
• The screen shows the input pattern beside.
• With "Interface no. for data out" you can enter a
serial interface (1 or 2) or a drive (A, B or C).
• If you send data to disks, this data will be sent in
the same format as with output to the serial
interface. This data have to be read in with DATA
IMPORT and must not be copied directly into the
workpiece directory.
Input pattern for data output
Example: Program output
• Press softkey PART PROGRAM
• The screen shows the input pattern beside
• Enter below mainprogram resp. subprogram the
following numbers:
Begin: the first program to be sent
End: the last program to be sent
• Press softkey MAINPRG START resp. SUBROUT
START. This will start the send function of the
software.
• With the softkey STOP you can interrupt data
output at any time, with MAINPRG START resp.
SUBROUT START you restart data output with
the first program to be sent.
Input pattern for data output - part program
Print Data
• Press softkey DATA OUT
• The screen shows the input pattern beside.
• With "Interface no. for data out" you can enter P to
select a printer.
• Act like data output
Example: Zero offset output
You can select to put out zero offsets or coordinate
rotations.
Channel-no. 0: Output zero offsets
Channel-no. 1: Output coordinate rotation
Data output zero offset - rotation
WinNC Sinumerik T (c) EMCO
x
F3 F4 F5 F6 F7
AUTOMATIC
DATA OUTPUT
Available memory: 63548 Zeichen
Interface no. for data out:
Interface allocation:
2
1 = RTS-LINE
2 = RTS-LINE
TOOL-
OFFSET
ZERO-
OFFSET
MACH.
DATA
PART-
PROGRAM
PLC-
M-DATA
WinNC Sinumerik T (c) EMCO
x
F3 F4 F5 F6 F7
AUTOMATIC
DATA OUTPUT
Main program:
Begin: % 0
End: % 0
Subroutine:
Begin: L 0
End: L 0
Interface no. for data out: 2
Interface allocation: 1=RTS-LINE
2=RTS-LINE
EXT
START
MAINPRG
START
SUBROUT
START
STOP
AUTOMATIC
DATA OUTPUT ZERO OFFSET/ROTATION
Channel no.0
... ... ...
WinNC Sinumerik T (c) EMCO
x
AUTOMATIC
DATA OUTPUT
Available memory: 36987
Interface no. for data out: 1
...
WinNC Sinumerik T (c) EMCO
x
Comentarios a estos manuales