7.12 Key lock and write protection
Introduction
You can use this function to lock the keys or activate write protection to safeguard the saved
parameters.
Lock options
You have the following lock options:
Table 7-3 Meaning of the HART lock modes
Lock mode Meaning
0 The device can be operated by means of the keys and HART communication.
LA Keys on the transmitter are locked.
Exception:
Releasing key lock
The device can be operated by means of HART communication.
LO Keys on the transmitter are partially locked.
Exception:
Setting start of scale value
Releasing key lock
The device can be operated by means of HART communication.
LS Keys on the transmitter are partially locked.
Exception:
Setting start of scale value
Setting full scale value
Releasing key lock
The device can be operated by means of HART communication.
LL Write protection
You can now only release the lock using HART communication.
See also
buttons and function lock
(Page 90)
Releasing key lock or function lock (Page 91)
Operating functions through HART
7.12 Key lock and write protection
SITRANS P, DS III series with HART