ST800 Guidance Notes
Issue 1 667/HB/27000/100 Page 7
Checks that the lamp supply and voltage monitors are detecting no mains
L/Supply Off=240V
L/Supply Stuck On
If a lamp supply is being detected, then this implies that the lamp supply
relays are all switched on (very unlikely) or the lamp supply monitoring
transformer (in the power distribution unit) or its connection to the first lamp
switch card is incorrect.
V/Mons Off...Failed
R-00000000+00000400
A-00000000+00000000
G-00000400+00000000
If any of the voltage monitors appear to be detecting mains, even though the
lamp supply and all the triacs are switched off, then this implies a problem
with the hardware on one or more of the lamp switch cards.
Initializes the phase bus processor
P/Bus Init...
LS/Card Fault (Lat)
Bad L/S Cards
Once initialized, the phase bus processor performs more thorough checks on
the lamp switch cards and may detect faults. These tests check the data lines
and board select lines using test latches on each card ‘(Lat)’, the address
lines to each card ‘(Adr)’ and the ADC test voltages ‘(ADC)’. If more than one
test fails, then ‘Bad L/S Cards’ is displayed instead.
Checks the monitor validation signal
M/V Test.....Failed
Mon Val Failed
The monitor validation signal is generated by the main processor and travels
down the phase bus cables to each of the lamp switch cards, so a failure is
probably due to a faulty lamp switch card.
At this point, the self test has successfully checked-out the logic side of all the lamp
switch cards that it has found. It then displays a scrolling diagonal line on the amber
LED’s on these lamp switch cards to prove that it can address all the boards
correctly and to show that the first part of the self-test is complete.
This pattern remains until the operator presses the level 3 button to confirm that the
pattern is scrolling correctly on all the cards fitted and that the self test may switch
on the lamp supply and continue its tests.
Caution
It is essential that the correct number of lamp switch
cards have been detected at this point as following this,
the self test will start applying mains to the signals
Vista de pagina 6