ST800 Guidance Notes
Page 14 667/HB/27000/100 Issue 1
FLF ABBR FLD Description
11
MEM
5 Memory Fault:
The allocation of the fault data will change:
FLD 5:00000001 - Program PROM checksum failure
FLD 5:00000010 - Config. PROM checksum failure
FLD 5:00000100 - RAM read/write test failure
FLD 5:00001000 - RAM junction data corrupt
FLD 5:00010000 - RAM timings data corrupt
FLD 5:00100000 - RAM rolling log or time/date corrupt
12
DFM
20-31 DFM Failure (FLD 20 for port 0 to FLD 31 for port 11)
13
IOB
79 Expansion I/O Board Missing (as T400)
14
CFGM
- On-Street Config. Mode Active (not available in the UK)
15
NEWC
- Configuration PROM Changed, enter the initialization codes
16
NEWF
- New Firmware Installed (or RAM corrupt on power-up)
17
LSUP
- Lamp Supply Failure:
The lamp supply has dropped below a configurable
threshold (i.e. mains supply below thresholds set by LBT and
LDT) or is simply not present (e.g. fuse blown).
18
PDFM
32 Priority DFM Failure
19
SDEP
- SDE/SA Board Failure On Power-Up
20
SDEF
6 SDE/SA Board Operating Failure
21
CPAT
7-9 Configuration / Firmware Not Compatible
Fault data consists of a fault id code (FLD7) plus two data
bytes:-
0 - No Fault
1 - Compatibility Number (Firmware and Config. Numbers)
2 - Facilities Table (Entry Number and Value)
3 - Unknown Configuration Item (2 Byte Item Identity)
4 - Invalid Configuration Data (2 Byte Item Identity)
5 - Lamp Sequence Command (Phase and Command)
6 - Conditioning Command (Command Code and ‘0’)
7 - Conditioning Timer Out of Range (2 byte timer number)
8 - Access Outside Conditioning Array (2 byte offset)
22
RLM
83-90 RLM Failure:
FLF 22:1 - 1st red fail active.
FLF 22:2 - 2nd red fail active.
FLF 22:3 - 1st and 2nd red fail active.
The fault log data will indicate on which phases the red lamp
failures have occurred:
FLD 83:11000011 - 1st/2nd red fails on phases A-D
FLD 84:00110000 - 1st/2nd red fails on phases E-H
FLD 85:00000000 - 1st/2nd red fails on phases I-L
FLD 86:00000000 - 1st/2nd red fails on phases M-P
...through to...
FLD 90:00000000 - 1st/2nd red fails on phases C2-F2
23
PED
- Special Conditioning - Pedestrian Controller Fault
24
LRT
- Special Conditioning - LRT Fault
25
LGRN
16-17 Special Conditioning - Limit Green Watchdog
26
HURY
- Special Conditioning - Hurry Call Monitor Fault