ST800 Guidance Notes
Issue 1 667/HB/27000/100 Page 13
FLF ABBR FLD Description
4
RLAY
3 Relay Tests Failed:
The relay tests try to detect short-circuits while the controller
is operating normally with the lamp supply on. By closing all
but the relay under test, the lamp supply should not be
present unless that relay is short circuit. Note that if any
relay is stuck open circuit, then the lamp supply fault (FLF17)
will detect no lamp supply.
The fault log data will indicate the detected fault:
FLD 1:00000001 - Relay A appears to be short circuit
FLD 1:00000010 - Relay B appears to be short circuit
FLD 1:00000100 - SSR appears to be stuck short circuit
Note that the test on the SSR may fail if there are no lamps
connected to the controller.
5
CFT
50-65 Green Conflict Detected:
This fault indicates that the main processor detected a green
conflict in the lamp states it requested. The first 4 bytes
show the conflicting phases.
FLD 50:01000100 - Conflicting phases A-H
FLD 51:00000000 - Conflicting phases I-P
FLD 52:00000000 - Conflicting phases Q-X
FLD 53:00000000 - Conflicting phases Y-F2
The next 12 fault data bytes show the requested lamp
states:
FLD 54:00111001 - Requested reds A-H
FLD 55:00100010 - Requested ambers A-H
FLD 56:11000100 - Requested greens A-H
FLD 57:11100000 - Requested reds I-P
...through to...
FLD 65:00000000 - Requested greens Y-F2
6
NZXO
- No ZXO detected
7
RTC
- RTC Power Fail Exceeded Configured Time - clock needs
setting up.
8
WDOG
4 Watchdog Tripped
FLD 4:00000001 - hardware watchdog timed-out
FLD 4:00000010 - TWD=1 entered on handset
FLD 4:00000100 - 20ms execution count incorrect
FLD 4:00001000 - 200ms execution count incorrect
FLD 4:00010000 - ZXO/peak execution count incorrect
FLD 4:00100000 - Problem with the main CPU operating
frequency
FLD 4:01000000 - Not Used
FLD 4:10000000 - 200ms routines have stopped
9 - Not Used
10 - Not Used