Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 28/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
To test the laser scanner SIMATIC FS600, carry out the following actions:
Response No. Action
1
Make sure that no objects
are located in either the
warning zone, or the
detection zone
ON OFF OFF ON OFF
2
Place an object into the
warning zone of the laser
scanner SIMATIC FS600.
ON ON OFF ON OFF
3
Place an object into the
detection zone of the laser
scanner SIMATIC FS600.
OFF
ON ON OFF OFF
Note
To reset a fault indication of the laser scanner SIMATIC FS600, the
following conditions must be satisfied:
• the fault has been eliminated
• “1” signal is received by the SIMATIC FS600 via the restart button.
Comentarios a estos manuales