Siemens SIMATIC FS600 Instrucciones de operaciones Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
Distributed Use of SIMATIC FS600 Laser
Scanner in Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 14/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
3 Required components
Hardware components
Component Type MLFB / Order information No. Manufacturer
Power supply PS307 5A 6ES73071EA00-0AA0 1
S7-CPU, can be used
for safety applications
CPU 315F-2DP 6ES7315-6FF01-0AB0
1
Micro Memory Card MMC 512 kBytes 6ES7953-8LJ11-0AA0 1
Interface module for ET 200S IM 151 High Feature 6ES7151-1BA02-0AB0 1
Power module for ET 200S PM-E DC24..48V AC24..230V 6ES7138-4CB11-0AB0 2
Electronic module for ET 200S 2DI HF DC24V 6ES7131-4BB01-0AB0 2
Electronic module for ET 200S 4/8 F-DI DC24V 6ES7138-4FA03-0AB0 1
Electronic module for ET 200S 4 F-DO DC24V/2A 6ES7138-4FB02-0AB0 1
Terminal module for ET 200S TM-P15S23-A0 6ES7193-4CD20-0AA0 2
Terminal module for ET 200S TM-E15S24-A1 6ES7193-4CA20-0AA0 2
Terminal module for ET 200S TM-E30C46-A1 6ES7193-4CF50-0AA0 2
Mounting rail 19.00 in 6ES7390-1AE80-0AA0 1
Standard mounting rail 35 mm, length:483 mm 6ES5710-8MA11 1
Push button Green, 1NO 3SB3801-0DA3 3
Push button Red, 1NC 3SB3801-0DB3 1
Position switch Overtravel plunger, 1S+1Ö 3SE5232-0HC05 2
Indicator light with lamp Yellow 3SB3217-6AA30 1
Laser scanner SIMATIC FS600 for PROFIBUS 3SF7834-6PB00 1
Optical PC adapter cable 3RG7838-1DC 1
PROFIBUS M12 connecting plug Pin insert (5 ea) 6GK1905-0EA00 1
PROFIBUS M12 connecting plug Connector insert (5 ea) 6GK1905-0EB00 1
PROFIBUS M12 connecting plug (5 ea) 6GK1905-0EC00 1
SIEMENS AG
Note
The functionality was tested using above hardware components. Similar
products not included in the above list can also be used. Please note that
in this case changes in the sample code (e.g. different addresses) may
become necessary.
Note
The HF electronic modules can be replaced by standard modules. One
4DI electronic module can be used instead of two 2DI electronic modules.