Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 25/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
The wizard can also be used to specify which zone pairs can be changed
over. In the safety functional example, it is allowed to switch from zone pair
1 to 2 and from zone pair 2 to 1.
4.4 Function test
The inputs and outputs used can be checked with regard to their
functionality if the following conditions are met:
• the hardware components are wired
• the STEP 7 project was loaded into the S7-CPU
• the following file was transmitted to the laser scanner SIMATIC FS600:
as_fe_i_010_v10_code_plscanner.ls.
Inputs/outputs used
No. HW component Address Symbol Signal
(default
value)
Note
1 Push button (NO) E 0.0 START “0” Switches the indicator light on
2 Push button (NC) E 0.1 STOP “1” Switches the indicator light off
3 Push button (NO) E 1.0 ACK “0“ Acknowledgement
4 Position switch 1 (NC) E 2.0 SEN_FIELD1 “1“
5 Position switch 2 (NC) E 2.4 SEN_FIELD2 “1“
Defining which zone pair is active.
6 Actuator (indicator light) A 8.0 ACTUATOR “0” Simulates a hazardous machine.
“0“ signal: "Machine" is switched
off