Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 42
7.6 Monitoring data output using the SOPAS ET terminal via Ethernet
To do so, open the SOPAS ET terminal and set up a connection via Ethernet on Port 2111 (or 2112).
Only a data format that contains STX/ETX framing can be monitored via Ethernet.
For correct representation in the SOPAS ET terminal, a CR LF at the end is also advisable. The most simple
method is therefore to select a suitable output format as Output Format 2 and assign it to the USB port.
Monitoring data via Ethernet Port 2111: