Semiconductor Group 5 - 12
On-Chip Peripheral Components
The following table 5-4 lists the SFR’s with their addresses and default values after reset which are
used in compare mode 2:
Table 5-4, Compare Mode 2, used SFR’s and their default Reset Value
The compare registers COMSET and COMCLR have their dedicated interrupt vectors. The
corresponding request flags are ICS for register COMSET and ICR for register COMCLR. The flags
are set by a match in registers COMSET and COMCLR, when enabled. As long as the match
condition is valid the request flags can’t be reset (neither by hardware nor software). The request
flags are located in SFR CTCON.
Special Function Register CTCON
The default value of CTCON after reset is 0X00 0000B
SFR Address Default Value after Reset
COMSETL 0A1
H
00
H
COMSETH 0A2
H
00
H
COMCLRL 0A3
H
00
H
COMCLRH 0A4
H
00
H
SETMSK 0A5
H
00
H
CLRMSK 0A6
H
00
H
CTCON 0E1
H
0X00 0000
B
CC4EN 0C9
H
00
H
Bit Function
CLK0
CLK1
CLK2
CTF
Same function as SAB 80C517
ICS Interrupt request flag for Compare register COMSET. ICS is set when a compare
match occured. Cleared when interrupt is processed.
ICR Interrupt request flag for Compare register COMRES. ICR is set when a compare
match occured. Cleared when interrupt is processed.
T2PS1 Prescaler select bit for Timer 2. See table 5-5
76543210
MSB LSBBit No.
CTCON0BA
H
T2PS1
ICR ISC CTF CLK2 CLK1 CLK0
Vista de pagina 46