Semiconductor Group 5 - 5
On-Chip Peripheral Components
Special Function Registers ADCON0, ADCON1
The reset value of ADCON0 and ADCON1 is 00
H
Bit Function
ADEX Internal / external start of conversion.
When set, the external start of conversion by P6.0 / ADST
is enabled.
BSY Busy flag.
This flag indicates whether a conversion is in progress (BSY = 1). The flag is
cleared by hardware when the conversion is finished.
ADM A/D Conversion mode.
When set, a continous conversion is selected.
If cleared, the converter stops after one conversion.
MX3 - MX0 Select 12 input channels of the ADC.
Bits MX0 to MX2 con be written or read either in ADCON0 or in ADCON1.
ADCL ADC Clock.
When set
f
ADC
= f
OSC
/ 16. Has to be set when f
OSC
> 16 MHz
76543210
MSB LSB
Bit No.
76543210
MSB LSB
Bit No.
ADCON0
ADCON1
Addr. 0D8
H
Addr. 0DC
H
These bits are not used in controlling A/D converter functions in the 80C517A
BD CLK ADEX BSY ADM MX2 MX1 MX0
MX2 MX1 MX0ADCL MX3
Vista de pagina 39