5-3
5.2.2 Inspection before Power On:
(1) Make sure that the machine's power source is according
to machine requirement.
(2) Make sure power cable diameter is 14mm
2
, and correctly
connected phases.
(3) Make sure that outside grounding is installed.
(4) Make sure that the power supply side is fitted breaker
with sensitivity specification 30mA.
(5) Make sure the cabinet is well closed.
(6) Make sure all the foundation bolts are securely tightened.
(7) Make sure that fix brackets are removed.
(8) Make sure the chuck is tightly mounted, and there is
nothing loose.
(9) Make sure that lubrication oil is full in lubrication oil
tube.
(10) Make sure that hydraulic oil tank is already filled with
suitable quantity of oil.
(11) Make sure there is nothing loose on turret, and there is
not sliding dropped problem.
(12) Make sure that the limit switch which control axis travel
and dog are not loosen.
(13) Make sure that the spindle drive belt is assembled with
suitable tension.
(14) Check if oil pipe or coolant pipe have any breakage or
looseness.
(15) Make sure that the protecting guard and safety door are
well closed.
(16) Make sure that there is no irrelevant objects nearby.
(17) Make sure the EMERGENCY STOP switch button is at
OFF condition.
(18) Make sure all pressure indicator is at "0" position.
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 112 113

Comentarios a estos manuales