SINAMICS G120
Inverter chassis units 0.37 kW to 132 kW (0.5 hp to 200 hp)
SINAMICS G120 chassis units
3/6
Siemens D 11.1 · 2008
3
■
Design (continued)
Available optional power and DC link components
depending on the used Power Module
The following line-side power components, DC link components
and load-side power components are optionally available for the
Power Modules in the corresponding frame sizes:
U = Base component
S = Lateral mounting
I = Integrated
F = Power Modules available without and with integrated filter class A
– = Not possible
Frame size
FSA FSB FSC FSD FSE FSF
Power Module PM240 with integrated brake chopper
Available frame sizes ✓ ✓ ✓ ✓ ✓ ✓
Line-side power components
Line filter class A
U F F F F F/S
3)
Line filter class B U U U – – –
Line reactor
U U U U U S
DC link components
Braking resistor
U U S S S S
Load-side power components
Output reactor
U U U S S S
Sine-wave filter
Available soon Available soon Available soon Available soon Available soon Available soon
Power Module PM250 with line-commutated regenerative feedback and intergrated line filter class A
Available frame sizes – – ✓ ✓ ✓ ✓
Line-side power components
Line filter class A
– – I I I I
Line filter class B
– – U – – –
Line reactor
1)
– – –
1)
–
1)
–
1)
–
1)
DC link components
Braking resistor
2)
– – –
2)
–
2)
–
2)
–
2)
Load-side power components
Output reactor
– – U S S S
Sine-wave filter
– – Available soon Available soon Available soon Available soon
Power Module PM260 with line-commutated regenerative feedback and intergrated sine-wave filter
Available frame sizes – – – ✓ – ✓
Line-side power components
Line filter class A
– – – F – F
Line filter class B
– – – – – –
Line reactor
1)
– – – –
1)
– –
1)
DC link components
Braking resistor
2)
– – – –
2)
– –
2)
Load-side power components
Output reactor
– – – – – –
Sine-wave filter
– – – I – I
1)
In connection with a PM250 or PM260 Power Module a line reactor is not
necessary and may not be used.
2)
In connection with a PM250 or PM260 Power Module a line-commutated
regenerative feedback is carried out. A braking resistor cannot be con-
nected and is not necessary.
3)
PM240 FSF Power Modules from 110 kW (150 hp) on are only available
without integrated filter class A. Therefore an optional line filter class A is
available for lateral mounting.
Comentarios a estos manuales