Siemens CU240S DP Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
SINAMICS G120
Inverter chassis units 0.37 kW to 132 kW (0.5 hp to 200 hp)
PM240 Power Modules
3/24
Siemens D 11.1 · 2008
3
Selection and Ordering Data
To ensure correct selection of the Power Module, it should be
chosen according to the
rated output current for applications with light overload
(LO) or
base-load current for applications with high overload (HO)
With reference to the rated output current, the modules support
at least 2-pole to 6-pole standard low-voltage motors, e.g. the
new 1LE1 motor series (please refer to the Appendix for further
information). The rated power is merely a guide value. For a
description of the overload performance, please refer to the gen-
eral technical data of the Power Modules.
Rated power
1)
Rated output
current
2)
I
rated
Power
based on the
base load current
3)
Base load
current
3)
I
H
Frame size SINAMICS G120
Power Module PM240
without
integrated line
filter
SINAMICS G120
Power Module PM240
with
integrated line filter
(class A)
kW hp A kW hp A Order No. Order No.
380 … 480 V 3 AC
0.37 0.50 1.3 0.37 0.50 1.3 FSA 6SL3224-0BE13-7UA0
0.55 0.75 1.7 0.55 0.75 1.7 FSA
6SL3224-0BE15-5UA0
0.75 1.0 2.2 0.75 1.0 2.2 FSA
6SL3224-0BE17-5UA0
1.1 1.5 3.1 1.1 1.5 3.1 FSA
6SL3224-0BE21-1UA0
1.5 2.0 4.1 1.5 2.0 4.1 FSA
6SL3224-0BE21-5UA0
2.2 3.0 5.9 2.2 3.0 5.9 FSB
6SL3224-0BE22-2UA0 6SL3224-0BE22-2AA0
3.0 4.0 7.7 3.0 4.0 7.7 FSB
6SL3224-0BE23-0UA0 6SL3224-0BE23-0AA0
4.0 5.0 10.2 4.0 5.0 10.2 FSB
6SL3224-0BE24-0UA0 6SL3224-0BE24-0AA0
7.5 10 18 5.5 7.5 13.2 FSC
6SL3224-0BE25-5UA0 6SL3224-0BE25-5AA0
11.0 15 25 7.5 10 19 FSC
6SL3224-0BE27-5UA0 6SL3224-0BE27-5AA0
15.0 20 32 11.0 15 26 FSC
6SL3224-0BE31-1UA0 6SL3224-0BE31-1AA0
18.5 25 38 15.0 20 32 FSD
6SL3224-0BE31-5UA0 6SL3224-0BE31-5AA0
22 30 45 18.5 25 38 FSD
6SL3224-0BE31-8UA0 6SL3224-0BE31-8AA0
30 40 60 22 30 45 FSD
6SL3224-0BE32-2UA0 6SL3224-0BE32-2AA0
37 50 75 30 40 60 FSE
6SL3224-0BE33-0UA0 6SL3224-0BE33-0AA0
45 60 90 37 50 75 FSE
6SL3224-0BE33-7UA0 6SL3224-0BE33-7AA0
55 75 110 45 60 90 FSF
6SL3224-0BE34-5UA0 6SL3224-0BE34-5AA0
75 100 145 55 75 110 FSF
6SL3224-0BE35-5UA0 6SL3224-0BE35-5AA0
90 125 178 75 100 145 FSF
6SL3224-0BE37-5UA0 6SL3224-0BE37-5AA0
110 150 205 90 125 178 FSF
6SL3224-0BE38-8UA0
132 200 250 110 150 205 FSF
6SL3224-0BE41-1UA0
1)
Rated power based on the rated output current I
rated
. The rated out-
put current
I
rated
is based on the loading for light overload (LO).
2)
The rated output current
I
rated
is based on the loading for light overload
(LO). These current values are quoted on the rating plate of the Power
Module.
3)
The base load current I
H
is based on the loading for high overload
(HO).
© Siemens AG 2008
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 81 82

Comentarios a estos manuales