SINAMICS G120
Inverter chassis units 0.37 kW to 132 kW (0.5 hp to 200 hp)
PM240 Power Modules
3/29
Siemens D 11.1 · 2008
3
■
Technical specifications (continued)
Line voltage
380 … 480 V 3 AC
PM240 Power Modules
Without integrated line filter 6SL3224-
0BE13-7UA0
6SL3224-
0BE15-5UA0
6SL3224-
0BE17-5UA0
6SL3224-
0BE21-1UA0
6SL3224-
0BE21-5UA0
Output current at 400 V 3 AC
• Rated current I
rated
1)
A 1.3 1.7 2.2 3.1 4.1
• Base load current
I
L
1)
A 1.3 1.7 2.2 3.1 4.1
• Base load current
I
H
2)
A 1.3 1.7 2.2 3.1 4.1
•
I
max
A 2.6 3.4 4.4 6.2 8.2
Rated power
• based on I
L
kW (hp) 0.37 (0.5) 0.55 (0.75) 0.75 (1.0) 1.1 (1.5) 1.5 (2.0)
• based on
I
H
kW (hp) 0.37 (0.5) 0.55 (0.75) 0.75 (1.0) 1.1 (1.5) 1.5 (2.0)
Rated pulse frequency kHz
4 4 4 4 4
Efficiency
!
0.97 0.97 0.97 0.97 0.97
Power loss kW
0.1 0.1 0.1 0.1 0.11
Cooling air requirement m
3
/s 0.005 0.005 0.005 0.005 0.005
Sound pressure level
L
pA
(1 m)
dB
< 45 < 45 < 45 < 45 < 45
24 V DC power supply
for Control Unit
A
1 1 1 1 1
Rated input current
3)
• with line reactor A 1.4 1.8 2.3 3.2 4.3
• without line reactor A
1.7 2.1 2.6 3.9 4.9
Length of cable to braking resistor,
max.
m
15 15 15 15 15
Line supply connection
U1/L1, V1/L2, W1/L3
Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals
• Conductor cross-section mm
2
1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5
Motor connection
U2, V2, W2
Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals
• Conductor cross-section mm
2
1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5
DC link connection,
connection for braking resistor
DCP/R1, DCN, R2
Screw terminals Screw terminals Screw terminals Screw terminals Screw terminals
• Conductor cross-section mm
2
1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5 1 … 2.5
PE connection
On housing with
M4 screw
On housing with
M4 screw
On housing with
M4 screw
On housing with
M4 screw
On housing with
M4 screw
Motor cable length
4)
, max.
• Shielded m 50 50 50 50 50
• Unshielded m
100 100 100 100 100
Degree of protection
IP20 IP20 IP20 IP20 IP20
Dimensions
• Width mm 73 73 73 73 73
• Height mm
173 173 173 173 173
• Depth
- without Control Unit mm 145 145 145 145 145
- with Control Unit mm
210 210 210 210 210
Frame size
FSA FSA FSA FSA FSA
Weight, approx. kg
1.1 1.1 1.1 1.1 1.1
1)
The rated output current
I
rated
and the base load current I
L
are based on
the loading for light overload (LO).
2)
The base load current
I
H
is based on the loading for high overload (HO).
3)
The input current depends on the motor load and line impedance. The
input currents apply for a load representing the rated power (based on
I
rated
) for a line impedance corresponding to u
K
= 1 %. These current val-
ues without line reactor are quoted on the rating plate of the Power Module.
4)
Max. motor cable length 25 m (shielded) for PM240 Power Modules with
integrated line filter to maintain the limit values of EN 61800-3 Category C2.