CP143 H1 / TCP/IP manual Network planning
Rev. 00/07 3-5
3.2.1 Thin-ethernet-cable network-layout
Here follows a summary of the restrictions and the rules that apply to a thin-ethernet-cable network.
Fig. 3-3 is an illustration of this summary.
Restrictions
Maximum number of network segments:
5 (3 coaxial segments with network
stations and 2 interconnecting segments
without network stations)
Maximum length of a network segment:
185 m
Maximum total length of the network cable:
925 m
Maximum number of network stations on a
segment:
30 (every repeater is counted as a station)
Minimum distance between two BNC-T-pieces:
0,5 m