Example CP143 H1 / TCP/IP manual
6-24 Rev. 00/07
Station 2
Enter the following values for station 2:
Connection name: RECEIVE from Station 1
Job number: 12
Priority: 2
Type of job: RECEIVE
TSAP local station (ASCII): receive
TSAP remote station (ASCII): send
Adr. remote st.: enter the ethernet address of station 1.
Fig. 6-14: H1 transport parameter station 2
Click on [OK] when you have completed the entries. You will be asked whether the connection
should be accepted. Please confirm to enable the connection. This concludes the configuration of
the different connections for the respective stations.
Re: 4. Save base data
Save the connection for the respective station. From menu item File (Datei) select the entry Save
(Speichern).
Enter "CP1.NCS" for the file name where the base data must be saved.
Repeat these activities for station 2 but use the file name "CP2.NCS".