CP143 H1 / TCP/IP manual Commissioning
Rev. 00/07 6-29
Station 2
Enter the following values for station 2:
• Connection name: RECEIVE from Station 1
• Job number: 12
• Priority: 2
• Type of job: RECEIVE
• Port local station: 00200
• Port remote station: 00100
• IP-Adr. remote St.: Enter the IP address of Station 1.
Fig. 6-21: TCP transport parameters station 2
Click on [OK] when you have completed the entries. You will be asked whether the connection
should be accepted. Please confirm to enable the connection. This concludes the configuration of
the different connections for the respective stations.
Re: 4. Save base data
Save the connection for the respective station. Select the entry Save (Speichern) from menu item
File (Datei).
Enter "CP1.NCS" for the file name where the base data must be saved.
Repeat these activities for station 2 but use the file name "CP2.NCS".