Configuration
42
Siemens Building Technologies
Fire Safety & Security Products 04.2006
10.5.6 Configuring other settings
1. Open the unit’s home page. See Section 7.4 Accessing the unit’s home page.
2. In the Configuration menu, select the menu option Camera and the Other
Settings suboption.
Î The Other Settings dialog will appear:
Fig. 12 Other settings
3. Enter the desired settings in this dialog.
Gain
z OFF
Minimal gain. If this option is selected, D/N mode (AUTO) is deactivated.
z NORMAL
Default setting; gain = 24 dB
z TURBO
High sensitivity setting; gain = 30 dB
BLC z OFF
The BLC function is deactivated.
z BLC1
The back light compensation window appears as follows (center 1 - smaller)
z BLC2
The back light compensation window appears as follows (center 2 - larger)
z BLC3
The back light compensation window appears as follows (top half)
z BLC4
The back light compensation window appears as follows (bottom half)
z BLC5
The back light compensation window appears as follows (top center)
z BLC6
The back light compensation window appears as follows (bottom center)
Gamma A gamma value between 0.45 and 1.0 can be selected here.
The standard value for CCTV monitors is generally 0.45.
For image processing purposes, 1.0 can be selected.
Aperture Set the image definition here (LOW, STANDARD, HIGH).
Chroma Choose a value between 1 and 8 for color intensity.
Mirror Select ON or OFF to activate or deactivate the mirror function.
4. Click Save.