RSSB Page 83 of 87
GSM-R user procedures (cab radio Version 2)
Displayed message
Meaning
Possible causes
Solution
Cab Radio Fault
Communications between the
control panel and the GSM-R cab
mobile is broken.
This fault shows when power is being
supplied to the cab mobile and the
drivers control panel and the
communications link between the two
has been broken. Likely to be an
electrical fault.
Treat in accordance with the rules as
a defective radio.
Inform maintenance.
RAM Test Failure or
EPROM Test
Start up failure of drivers control
panel.
Same as above but tested on
initialization.
Treat in accordance with the rules as
a defective radio.
Inform maintenance.
Failed
An attempt to send the standing at
signal operational text message has
failed.
There are a number of possible causes
mainly relating to communication
between the cab radio and the GSM-R
network.
Try again, if the message fails for a
second time, then you must remind
the signaller of the presence of your
train using an alternative method, for
example a point-to-point call.
Failed to activate
An attempt to activate Divert all
calls’ has failed.
A phone number that was not valid was
entered for the forwarded calls.
The network failed to set up the divert.
Do not use “Divert all calls”.
Failed to connect
A call, from the cab radio, could not
be made.
There could be several reasons for this
however the cab radio cannot tell what
the problem is.
Clear the failure message and try
again.