SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series for absolute pressure
(from gage pressure series)
2/95
Siemens FI 01 · 2009
2
Selection and Ordering data Order code
Further designs
HART PA FF
Add "-Z" to Order No. and specify Order
code.
Pressure transmitter with mounting
bracket made of:
•Steel A01 9
9
9
9
9
9
• Stainless steel A02 9
9
9
9
9
9
Plug
• Han 7D (metal, gray) A30 9
9
• Han 8U (instead of Han 7D) A31 9
9
Cable sockets for M12 connectors (metal) A50 9
9
9
9
9
9
Rating plate inscription
(instead of German)
• English B11 9
9
9
9
9
9
• French B12 9
9
9
9
9
9
• Spanish B13 9
9
9
9
9
9
• Italian
B14 9
9
9
9
9
9
English rating plate B21 9
9
9
9
9
9
Pressure units in inH
2
O or psi
Quality inspection certificate (Factory cali-
bration) to IEC 60770-2
1)
C11 9
9
9
9
9
9
Acceptance test certificate
2)
C12 9
9
9
9
9
9
To EN 10204-3.1
Factory certificate C14 9
9
9
9
9
9
To EN 10204-2.2
"Functional Safety (SIL)" certificate C20 9
9
"PROFIsafe" certificate and protocol C21 9
9
Setting of upper limit of output signal to
22.0 mA
D05 9
9
Manufacturer's declaration acc. to NACE D07 9
9
9
9
9
9
Type of protection IP68 D12 9
9
9
9
9
9
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator alongside the input keys D27 9
9
9
9
9
9
(only together with the devices 7MF4233-
....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01).
Supplied with oval flange D37 9
9
9
9
9
9
(1 item), PTFE packing and screws in thread
of oval flange
Use in or on zone 1D/2D E01 9
9
9
9
9
9
(only together with type of protection "Intrinsic
safety (EEx ia)")
Use on zone 0 E02 9
9
9
9
9
9
(only together with type of protection "Intrinsic
safety (EEx ia)")
Oxygen application E10 9
9
9
9
9
9
(max. 120 bar a (1740 psi a) at 60 °C (140 °F)
with oxygen measurement and inert liquid)
Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)
E25 9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion-proof "Intrinsic safety" to NEPSI
(China)
E55 9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.B..)
Explosion protection "Explosion-proof" to
NEPSI (China)
E56 9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.D..)
Explosion-proof "Zone 2" to NEPSI (China) E57 9
9
9
9
9
9
(only for transmitter 7MF4...-.....-.E..)
Additional data HART PA FF
Add "-Z" to Order No. and specify Order
code.
Measuring range to be set
Y01 9
9
Specify in plain text (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
Measuring point number (TAG No.) Y15 9
9
9
9
9
9
Max. 16 characters, specify in plain text:
Y15: ...........................................
Measuring point text Y16 9
9
9
9
9
9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Entry of HART address (TAG) Y17 9
9
Max. 8 characters, specify in plain text:
Y17: ...........................................
Setting of pressure indication in pressure
units
Y21 9
9
9
9
9
9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
bar, mbar, mm H
2
O
*)
, inH
2
O
*)
, ftH
2
O
*)
,
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
,
kg/cm
2
, Torr, ATM oder %
*) ref. temperature 20 °C
Setting of pressure indication in
non-pressure units
Y22 +
Y01
9
9
9
9
9
9
Specify in plain text:
Y22: ..... up to ..... l/min, m
3
/h, m, USgpm, ...
(specification of measuring range in pressure
units "Y01" is essential, unit with
max. 5 characters)
Preset bus address Y25 9
9
(possible between 1 and 126)
Specify in plain text:
Y25: .....................
Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset
9
9
= available
1)
When the manufacture’s certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total
combination is certified here.
2)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
Selection and Ordering data Order code
© Siemens AG 2008