SITRANS P measuring instruments for pressure
Transmitters for gage pressure for the paper industry
DS III series with PMC connection
2/55
Siemens FI 01 · 2009
2
Selection and Ordering data Order No.
SITRANS P pressure transmitters for gage
pressure, with PMC connection
series DS III HART
7 M F 4 1 3 3 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling Measuring cell
cleaning
Silicone oil Standard 1
Inert liquid Grease-free 3
Span
0.01 ... 1 bar g
1)
1)
Only with "PMC Style Standard" process connection
(0.15 ... 14.5 psi g)
1)
B
0.04 ... 4 bar g (0.58 ... 58 psi g) C
0.16 ... 16 bar g (2.32 ... 232 psi g) D
Wetted parts materials
Seal diaphragm Connection shank
Hastelloy Stainless steel B
Process connection
• PMC Style Standard: Thread 1½" 2
• PMC Style Mini bolt: 1" front-flush (min. span:
500 mbar (7.25 psi), can not be ordered with mit
1-bar (14.5 psi) measuring cell (Option B))
3
Non-wetted parts materials
• Housing made of die-cast aluminum 0
• Housing stainless steel precision casting 3
Version
• Standard version 1
• International version, English label inscriptions,
documentation in 5 languages on CD
2
Explosion protection
• None A
Electrical connection / cable entry
• Female thread M20x1.5 B
• Female thread ½-14 NPT C
• M12 connectors (metal) F
Display
• Without indicator 0
• Without visible digital indicator (digital indicator
hidden, setting: mA)
} 1
• With visible digital indication, setting: mA 6
With customer-specific digital indication (setting
as specified, Order code "Y21" or "Y22"
required)
7
Power supply units see "SITRANS I power supply units and isolation
amplifiers".
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing ring
Selection and Ordering data Order No.
SITRANS P pressure transmitter for gage
pressure, with PMC connection
DS III PA (PROFIBUS PA) series 7 M F 4 1 3 4 -
DS III FF series (FOUNDATION Fieldbus) 7 M F 4 1 3 5 -
7 7 7 7 7
-
7 7 7 7
Measuring cell filling Measuring cell
cleaning
Silicone oil Standard 1
Inert liquid Grease-free 3
Nominal measuring range
1 bar g
1)
1)
Only with "PMC Style Standard" process connection
(14.5 psi g)
1)
B
4 bar g (58 psi g) C
16 bar g (232 psi g) D
Wetted parts materials
Seal diaphragm Connection shank
Hastelloy Stainless steel B
Process connection
• PMC Style Standard: front-flush 1½" 2
• PMC Style Mini bolt: front-flush 1"
(min. span: 500 mbar (7.25 psi), can not be or-
dered with mit 1-bar (14.5 psi) measuring cell
(Option B))
3
Non-wetted parts materials
• Housing made of die-cast aluminum 0
• Housing stainless steel precision casting 3
Version
• Standard version 1
• International version, English label inscriptions,
documentation in 5 languages on CD
2
Explosion protection
• None A
Electrical connection / cable inlet
• Screwed gland M20x1.5 B
• Screwed gland ½-14 NPT C
• M12 connectors (metal) F
Display
• Without indicator 0
• Without visible digital indicator (digital indicator
hidden, setting: mA)
} 1
• With visible digital display 6
With customer-specific digital display (setting as
specified, Order code "Y21" or required)
7
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
• Sealing ring
© Siemens AG 2008