SITRANS P measuring instruments for pressure
Diaphragm seals of flange design
For differential pressure,
fixed connection and with capillary
2/168
Siemens FI 01 · 2009
2
Selection and Ordering data Order No. Ord. code
Diaphragm seal
D)
7 M F 4 9 1 3 -
Mounting flange (with tube as option) for
direct mounting to high-pressure side and
flanged remote seal without tube, fitted by
means of capillary to low-pressure side of
SITRANS P for differential pressure, DS III series
(7MF443
7)
1
7 7 7 7
-
7
B
7 7 7
Flange, connection to EN 1092-1
Nom. diam. Nom. press.
•DN80 PN40 D
• DN 100 PN 16 G
PN 40 H
Flange, connection to ASME B16.5
Nom. diam. Nom. press.
• 3 inch Class 150 Q
Class 300 R
• 4 inch Class 150 T
Class 300 U
Other version
Add Order code and plain text:
Flange: ..., Nominal diameter: ...; Nominal
pressure: ...
Z J 1 Y
Wetted parts materials
Smooth sealing face to EN 1092-1, form B1 or
B2, or to ASME B16.5 RF 125 ... 250 AA or RFSF
• Stainless steel 316L
- without foil A
- with PTFE coating E 0
- with ECTFE coating
1)
F
- with PFA coating D
• Monel 400, mat. No. 2.4360 G
• Hastelloy C276, mat. No. 2.4819 J
• Hastelloy C4, mat. No. 2.4610 U
• Tantalum K
Other version
Add Order code and plain text:
Wetted parts materials: ...
Z K 1 Y
Tube length
(for mounting flange on high-pressure side)
• Without tube 0
• 50 mm (1.97 inch) 1
• 100 mm (3.94 inch) 2
• 150 mm (5.90 inch) 3
• 200 mm (7.87 inch) 4
Other version:
Add Order code and plain text:
Tube length: ...
9 L 1 Y
Filling liquid
• Silicone oil M5 1
• Silicone oil M50 2
• High-temperature oil 3
• Halocarbon oil (for measuring O
2
) 4
• Glycerin/water
2)
6
• Food oil (FDA listed) 7
Other version
Add Order code and plain text:
Filling liquid: ...
9 M 1 Y
Length of capillary
3)
• 1.0 m (3.28 ft) 2
• 1.6 m (5.25 ft) 3
• 2.5 m (8.20 ft) 4
• 4.0 m (13.1 ft) 5
• 6.0 m (19.7 ft) 6
• 8.0 m (26.25 ft) 7
• 10.0 m (32.8 ft) 8
Other version
Add Order code and plain text:
Length of capillary: ...
9 N 1 Y
1)
For vacuum on request.
2)
Not suitable for use in low-pressure range.
3)
Max. capillary length, see section "Technical description".
D) Subject to export regulations AL: N, ECCN: EAR99H.
Selection and Ordering data Order code
Further designs
Please add "-Z" to Order No. and specify Order code.
Spark arrestor
With spark arrestor for mounting on zone 0 (including
documentation)
A02
Quality inspection certificate (Factory calibration) to
IEC 60770-2
C11
Acceptance test certificate
to EN 10204, section 3.1
C12
Vacuum-proof design
for use in low-pressure range
V03
Calculation of span of associated pressure
transmitter
Enclose filled-in questionnaire with order
Y05
Selection and Ordering data Order No. Ord. code
Diaphragm seal
D)
7 M F 4 9 1 3 -
Mounting flange (with tube as option) for
direct mounting to high-pressure side and
flanged remote seal without tube, fitted by
means of capillary to low-pressure side of
SITRANS P for differential pressure, DS III series
(7MF443
7)
1
7 7 7 7
-
7
B
7 7 7
© Siemens AG 2008