SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure
Z series for gage and absolute pressure
2/9
Siemens FI 01 · 2009
2
Please note:
• It is not possible to have a smaller span than the smallest span of the device of the entire device range.
• The value must not fall below the minimum permissible operating pressure of the special measuring range of the selected
measuring cell.
• The required span of the device must lie between the smallest and the largest possible span of the entire device range.
■
Selection and Ordering data Order No. Order code
SITRANS P pressure transmitters for pressure, series Z for gage and absolute pressure
2 or 3-wire system, rising characteristic curve
D)
7 MF 1 5 6 4 -
777 7 7
-
777
1
7 7 7
Measuring range perm. working pressure Burst pressure
Min. Max.
For gage pressure
with metal measuring cell
0 ... 100 mbar g (0 ... 1.45 psi g) -0,6 bar g (-8.7 psi g) 0,6 bar g (8.7 psi g) 1 bar g (14.5 psi g)
} 3AA 0
0 ... 160 mbar g (0 ... 2.32 psi g) -0,6 bar g (-8.7 psi g) 0,6 bar g (8.7 psi g) 1 bar g (14.5 psi g)
} 3AB 0
0 ... 250 mbar g (0 ... 3.63 psi g) -1 bar g (-14.5 psi g) 1bar g (14.5 psi g) 1.7 bar g (25 psi g)
} 3AC 0
0 ... 400 mbar g (0 ... 5.80 psi g) -1 bar g (-14.5 psi g) 1bar g (14.5 psi g) 1.7 bar g (25 psi g)
} 3AD 0
0 ... 600 mbar g (0 ... 8.70 psi g) -1 bar g (-14.5 psi g) 3bar g (43.5 psi g) 5 bar g (72 psi g)
} 3AG 0
Other version for measuring range < 1 bar (< 14.5 psi g), add Order code and plain text:
measuring range: ... up to ... mbar g (psi g)
1)
9AC 0 H 1 Y
with ceramic measuring cell
0 ... 1 bar g (0 ... 14.5 psi g) -0,4 bar g (-5.8 psi g) 2bar g (30 psi g) 5 bar g (72 psi g)
} 3BA
0 ... 1.6 bar g (0 ... 23.2 psi g) -0,4 bar g (-5.8 psi g) 3,2 bar g (45 psi g) 5 bar g (72 psi g)
} 3BB
0 ... 2.5 bar g (0 ... 36.3 psi g) -0,8 bar g (-11.6 psi g) 5bar g (72 psi g) 12 bar g (175 psi g)
} 3BD
0 ... 4 bar g (0 ... 58.0 psi g) -0,8 bar g (-11.6 psi g) 8bar g (115 psi g) 12 bar g (175 psi g)
} 3BE
0 ... 6 bar g (0 ... 87.0 psi g) -1 bar g (-14.5 psi g) 12 bar g (175 psi g) 25 bar g (360 psi g)
} 3BG
0 ... 10 bar g (0 ... 145 psi g) -1 bar g (-14.5 psi g) 20 bar g (290 psi g) 50 bar g (725 psi g)
} 3CA
0 ... 16 bar g (0 ... 232 psi g) -1 bar g (-14.5 psi g) 32 bar g (460 psi g) 50 bar g (725 psi g)
} 3CB
0 ... 25 bar g (0 ... 363 psi g) -1 bar g (-14.5 psi g) 50 bar g (725 psi g) 120 bar g (1750 psi g)
} 3CD
0 ... 40 bar g (0 ... 580 psi g) -1 bar g (-14.5 psi g) 80 bar g (1150 psi g) 120 bar g (1750 psi g)
} 3CE
0 ... 60 bar g (0 ... 870 psi g) -1 bar g (-14.5 psi g) 120 bar g (1750 psi g) 250 bar g (3600 psi g)
} 3CG
0 ... 100 bar g (0 ... 1450 psi g) -1 bar g (-14.5 psi g) 200 bar g (2900 psi g) 450 bar g (6525 psi g)
} 3DA
0 ... 160 bar g (0 ... 2320 psi g) -1 bar g (-14.5 psi g) 320 bar g (4640 psi g) 450 bar g (6525 psi g)
} 3DB
0 ... 250 bar g (0 ... 3626 psi g) -1 bar g (-14.5 psi g) 500 bar g (7250 psi g) 650 bar g (9425 psi g)
} 3DD
0 ... 400 bar g (0 ... 5802 psi g) -1 bar g (-14.5 psi g) 600 bar g (8700 psi g) 650 bar g (9425 psi g)
} 3DE
Other version for measuring range ≥ 1 bar g (≥ 14.5 psi g), add Order code and plain text:
measuring range: ... up to... bar (psi g)
1)
9AA H 1 Y
For absolute pressure
0 ... 600 mbar a (0 ... 8.7 psi a) 0 bar a (0 psi a) 3bar a (43.5 psi a) 5bar a (72 psi a)
}
J)
5AG 0
0 ... 1 bar a (0 ... 14.5 psi a) 0 bar a (0 psi a) 2bar a (30 psi a) 5bar a (72 psi a)
}
J)
5BA
0 ... 1.6 bar a (0 ... 23.2 psi a) 0 bar a (0 psi a) 3,2 bar a (45 psi a) 5bar a (72 psi a)
}
J)
5BB
0 ... 2.5 bar a (0 ... 36.3 psi a) 0 bar a (0 psi a) 5bar a (72 psi a) 12 bar a (175 psi a)
}
J)
5BD
0 ... 4 bar a (0 ... 58.0 psi a) 0 bar a (0 psi a) 8bar a (115 psi a) 12 bar a (175 psi a)
}
J)
5BE
0 ... 6 bar a (0 ... 87.0 psi a) 0 bar a (0 psi a) 12 bar a (175 psi a) 25 bar a (360 psi a)
}
J)
5BG
0 ... 10 bar a (0 ... 145 psi) 0 bar a (0 psi a) 20 bar a (290 psi a) 50 bar a (725 psi a)
}
J)
5CA
0 ... 16 bar a (0 ... 232 psi) 0 bar a (0 psi a) 32 bar a (460 psi a) 50 bar a (725 psi a)
}
J)
5CB
Other version for measuring range < 1 bar (< 14.5 psi a), add Order code and plain text:
measuring range: ... up to ... mbar a (psi a)
J)
9AB 0 H 1 Y
} Available ex stock D) Subject to export regulations AL: N, ECCN: EAR99H.
J) Subject to export regulations AL: 9I999, ECCN: EAR99.
1)
The transmitters can also be ordered with special measuring ranges, e.g. the transmitter with the 1 bar measuring cell (14.5 psi measuring cell):
-0.2 ... +0.8 bar g (-2.9 ... +11.6 psi g) or
-0.4 ... +0.6 bar g (-5.8 ... +8.7 psi g) or ..., however start-of-scale value not under -0.4 bar g (-5.8 psi g), also see column "min. perm. operating pressure"