20
Manual – MOVITOOLS® - Connection to SIMATIC S7 via MPI
4
Limited functionality of MOVITOOLS® with PROFIBUS-DP
Configuration and Start of MOVITOOLS®
Problems when
connecting to
MPI
Check the following setting in case you fail to establish an online connection to the SEW-
EURODRIVE drives:
• Number of inverters and address information in hardware data block (declaration
view)
• MPI communication parameters in MoviLinkSwitcher
You can use an integrated debugger to obtain more information which you can use for
diagnostics of your MPI connection. Select the [User Debug] option in the MoviLink-
Switcher to define the MPI connection and start the debugger with the [Start Debug-
ger] button. See the section "Appendix" for a description on how to proceed.
4.3 Limited functionality of MOVITOOLS
®
with PROFIBUS-DP
MOVITOOLS
®
with PROFIBUS DPV1 offers expanded functions for the acyclical ex-
change of parameter data. MOVITOOLS
®
uses the parameter channel with limited func-
tions when working with PROFIBUS-DP.
The following MOVITOOLS
®
functions are not available with PROFIBUS DPV0:
• MOVIDRIVE drive inverters
®
– MOVITOOLS
®
Scope
– Reading, saving, uploading and displaying the electronic nameplate with
MOVIDRIVE
®
compact
MCH...
– Storing parameter sets with more than one electronic cam
– Using the "Save data" function in the MOVITOOLS
®
Manager
• MOVITRAC
®
07 frequency inverter via PROFIBUS Gateway UFP11A
– MOVITOOLS
®
Scope
– Using the "Save data" function
– Using the "Save data" function in the MOVITOOLS
®
Manager
– Communication with MOVITRAC
®
07 frequency inverters which are connected to
PROFIBUS DPV0 via UFP11A
You cannot connect two or more different PG/PCs to the same PLC at the same time
with "MOVITOOLS
®
via MPI."
If you are using the PROFIBUS-DPV1 components (master and slave) as well as the
function data blocks of the VXXX_DPV1.ZIP file, you can use MOVITOOLS
®
without
limitations.