Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–19
2.6.3 Removing cover plate/lamp plate
Fig. 2-14 Removing cover plate/lamp plate
Procedure
Remove the bulbs from the holder by turning them anti-clockwise.
Insert the screwdriver into (a) and remove the cover plate (4) by lifting it over
the bevel of the lamp holder.
Repeat by inserting the screwdriver into (b).
Pull the cover plate (4) and flat cable (1) out of the stop bolts (2).
Carefully remove the lamp plate (3) from the stop bolts (2) by hand.
Lift the cover plate/lamp plate in the area of the distance counter and
remove without damaging the contact springs.
Turn the cover plate (4) and carefully pull the flat cable (1) out of the socket
connector.
1 Flat cable 3 Lamp plate
2 Stop bolts 4 Cover plate
1
2
2
4
3
b
a
Note
• The five stop bolts (2) hold the cover plates (4) and lamp plate (3) in place.
• When removing the two plates, do not press the stop bolts together.