Siemens BTC-BR Manual Pagina 241

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 240
Technical Product Manual
Fault analysis and repairs 1318
7 Wiring diagrams, fault analysis
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 7 7–13
Section 7: Wiring diagrams, fault analysis • Edition 12/2005
Error Component 1 Component 2
Component 1 voltage check Troubleshooting Resistance check Component 2 Troubleshooting
Measurin
g point
colour
Conductor
no. ()
12 V unit 24 V unit
Component 1 Visual check Component 2 Component 2
n= 0 rev/
min
n= 2000 rev/
min
v = 0 km/h n= 2000 rev/
min
Faulty RPM display H
v board
F
n board
Flat cable from H v
board to F
n board
Flat cable
18 ... 33 see component 2
Measuring value between v board and n board: 0 Ω Faulty measuring value.
Replace flat cable, check socket connector
contacts on v and n boards.
F
n board
B
DC motor
RPM
Flat cable
r 5 +
bk 4 +
((9))
((7))
0 V 2.3 ... 3.2 V 0 V 2.3 ... 3.2 V
Measuring value between points 4 and 5 (flat cable): 50 Ω ((7)) ((9)) Faulty measuring value.
Unsolder r and bk wire from lamp plate A and
repeat resistance measurement.
C
Potentiometer
Resistor
RPM
Flat cable
p 1 + ((1))
5.4 V 5 ... 6.2 V
Remove flat cable from v board.
Measuring value between points 1 and 2 (flat cable): 5 kΩ / ((1)) ((3))
Faulty measuring value.
Unsolder p, wt and wtr wires from lamp plate A
and repeat resistance measurement.
wsrt 3 + ((5)) 5.3 V 4.6 V 5.5 V 4 ... 4.8 V Measuring value between ((3)) and ((5)) wires: 600 Ω ... 5 kΩ.
The resistance value must increase and decrease steadily when adjusting the RPM
stylus lever slowly.
wt 2 + ((3))
3.8 V 2.8 ... 4.1 V
Flat cable from H v
board to A lamp
plate
Flat cable
1 ... 16 see component 2
Measuring value between v board and lamp plate: 0 Ω Faulty measuring value. Replace n board.
(Socket connector)
F
n board
G
Coding switch see component 2
Measuring device's negative pole to point 52 (underside of n board. Measuring
value between points 42 and 52 if switch set to "ON": 0 Ω.
Measuring value if switch set to "OFF": > 1.5 kΩ
Faulty measuring value. Replace n board.
H
v board
E
n test socket bl 17
Measuring value between test socket and v board 0Ω. Faulty measuring value. Replace cable.
External
n warning contact
defective
H
v board
D
n warning contact
Flat cable
7 + ((13))
0 V 12 V 0 V
24 V
(n max)
Faulty measuring value.
Unsolder ye wire from lamp plate.
Measuring value on ye wire and point 7 ((13))
:
not switched: :Ω
switched: 0Ω
to connector output C8
0 V 12 V 0 V
24 V
(n max)
ye 6 + ((11))
12 V 24 V
Apply a 0 V potential to A6 tab connector for the measuring device.
+ = Connect measuring device's positive cable. Measuring tolerance: ± 10 %
Measuring device: Multimeter –accuracy class 1.5 (>30.000 Ω /V)
= Visually check mechanical parts. = If defective, replace component 1 part (n board). = If defective, replace component 2 part.
=
Visually check electrical cables, components, soldered connections,
conductors and plug contacts.
= Measure ohmic resistance. (( )) Conductor no., 16-pin flat cable
=
Check gear engagement and that the gears from the DC motor to the
potentiometer are running freely.
= Remove flat cable.
= If defective, check, adjust or replace the relevant components. = Remove unit.
Vista de pagina 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 263 264