11 Alarms 09.91
11.11 Alarm list ACKNOWLEDGE
Cause:
Effect:
Remedy:
6103
Transfer to missing DB
L DW or T DW without prior ”opening”
(A DB ...) of a data block
PLC STOP
Check PLC program
Cause:
Effect:
Remedy:
6104
Substitution error
Parameterization error in BMW or BDW command
PLC STOP
Correct PLC program
Cause:
Effect:
Explanation:
Remedy:
6105
Missing MC 5 block
Unavailable block in control called
(OB, PB, SB, FB).
PLC STOP
OB2 not available, for example
Enter missing block
Cause:
Effect:
Remedy:
6106
DB missing
Unavailable data block in control called
PLC STOP
Enter missing DB
Cause:
Effect:
Explanation:
Remedy:
6107
Illegal segment LIR / TIR
LIR: Segment No. 0-A allowed
TIR: Segment No. 0-6 allowed
PLC STOP
Programming Guide LIR/TIR
Correct program
11–50 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02
SINUMERIK 810 GA3/820 GA3 (IA)
Comentarios a estos manuales