11.90 11 Alarms
11.11 Alarm list ACKNOWLEDGE
6000
:
6063
PLC user alarm
Explanation:
Remedy:
Initiation bit was set in the PLC user program
Check PLC program or machine function
6100
Signal converter missing
Cause:
Effect:
Remedy:
Load or transfer command to unavailable peripheral device
(I/Os), e.g. L PB, T PB
PLC STOP
Check peripheral address or STEP 5 program
6101
Illegal MC 5 code
Cause:
Effect:
Remedy:
STEP-5 instruction cannot be interpreted
PLC STOP
Check or reload PLC program
Evaluate ISTACK
6102
Illegal MC 5 parameter
Cause:
Effect:
Remedy:
Illegal parameter type (I, Q, F, C, T) or
illegal parameter value
PLC STOP
Check PLC program
Evaluate ISTACK
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02 11–49