Siemens SIMATIC NET PROFIBUS Manual de servicio Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 238
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
Description of the DP Functions, Data, and Error Codes
DP Base Programming Interface for CP 5613/CP 5614
82
C79000-G8976-C108-01
Parameters
Name Description
user_handle User handle assigned with the DP_open call.
slv_add
Address of the slave or 0xFF with the meaning: Activate or
deactivate AUTOCLEAR for all.
slv_mode Required slave state:
DP_SLV_ACTIVATE Activate the slave
DP_SLV_DEACTIVATE Deactivate the slave
AUTOCLEAR setting:
DP_AUTOCLEAR_ON Activate
DP_AUTOCLEAR_OFF Deactivate
The values can also be ORed.
error
Address of a structure provided by the user program of the
type DP_ERROR_T. If an error occurred, the structure
contains details for troubleshooting (see Section 4.4).
Return Value
Name Description
DP_OK Successful completion of the function
other Unsuccessful completion of the function
Vista de pagina 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 237 238

Comentarios a estos manuales

Sin comentarios