Example "Motion"
5.3 Configure technological object "Axis"
STEP 7 Basic V10.5
170 Getting Started, 12/2009, A5E02651459-01
5.3 Configure technological object "Axis"
Introduction
The following steps show you how to configure the technological object "Axis".
Requirements
The technological object "Axis" has been created.
The configuration of the technological object has been started.
If the configuration was not automatically opened, start the configuration from the project
tree.
Procedure
To configure the drive control, follow these steps:
1. Select the pulse output "Pulse_1" to the PTO drive control and switch to the device
configuration.
The high-speed counter "HSC_1" is automatically assigned during selection of "Pulse_1".
The device view opens.