Installation
20
Siemens Building Technologies
Fire Safety & Security Products 05.2009
7.1.2 Internet connection with static IP
Choose this connection type if you are required to use a static IP for the network
camera and proceed as follows.
1. Set up the network camera in the LAN (see chapter
8.5.2).
2. Go to Configuration > Network > Network Type.
3. Select LAN > Use fixed IP address.
4. Enter the static IP, Subnet mask, Default router, Primary DNS provided by
your ISP.
7.1.3 Internet connection via PPPoE (Point-to-Point over Ethernet)
Choose this connection type if you are connected to the Internet via a DSL Line
(see chapter
8.5.1: PPPoE setting).