7
User programming via the keypad
User Menus
28
Siemens AB
A6V10271018
Security Products
26.09.2011
7.1.2 ISOLATE
Zones, system alerts or alerts from X-BUS devices can be manually isolated from
the keypad. Isolating a zone removes that zone from the system until the user de-
isolates it.
To isolate zones, system alerts or alerts from X-BUS devices:
1. Scroll to ISOLATE and press SELECT.
2. Scroll to the desired option in the table below and press SELECT.
ZONE
Select the required zone and toggle the setting from NOT
ISOLATED to ISOLATED.
SYSTEM
Isolate the desired system alert.
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
XBUS COMMS LOST
XBUS FUSE FAULT (Expanders only)
X-BUS TAMPER
VIEW ISOLATIONS
To view a list of the isolated zones, system alerts and X-BUS
devices alerts.
7.1.3 INHIBIT
Zone and alerts from X-BUS devices can be manually inhibited from the keypad.
Inhibiting a zone removes that zone from the system for one alarm set period only.
To inhibit zones or alerts from X-BUS devices:
1. Scroll to INHIBIT and press SELECT.
2. Scroll to the desired option in the table below and press SELECT:
ZONES
Select the required zone and toggle the setting from NOT INHIBITED to
INHIBITED.
SYSTEM
Select the required system alert and toggle the setting from DISABLED to
ENABLED to inhibit it.
MAINS FAULT
BATTERY FAULT
AUX FUSE FAULT
EXT FUSE FAULTINT FUSE FAULT
BELL TAMPER
AUX 1 TAMPER
AUX 2 TAMPER
ANTENNA TAMPER
MODEM 1 L FAULT
MODEM 2 L FAULT
XBUS CABLE FAULT
FAIL TO REPORT
PSU FAULT
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
XBUS COMMS LOST
XBUS FUSE FAULT (Expanders only)